Tags:
view all tags
---+ NGAO Alignment, Calibration, and Diagnostics mini-review ---++ Questions and comments from Jim Lyke ---+++ KAON 719 ---++++ Sec. 2.4 Alignment Requirements * Focal plane alignment (x,y), 4th bullet: Does DAVINCI team know about instrument position requirement to 0.2 mm or a possible alignable coronographic field stop and has it been designed? * Pupil plane alignment (x,y), 1st bullet: Does DAVINCI team know about this 75 micron requirement? * Tilt (theta x, theta y), 2nd bullet: Would these off-axis aberations add to the WF error budget? Is there a rough calculation? * General question: Have requirements for xyz stage for the kinematic instrument mounts been fleshed out? If not, please consider discussing with DAVINCI team. * LGS WFS to AO bench * Focal plane alignment (x,y), 2nd bullet: Is this in the f/15 beam? If so, <0.2 arcseconds is <0.14 mm, which seems tight. What is the range of the fast TT mirrors? If 5", seems this could be relaxed by a factor of 2 without losing much dynamic range and still be smaller than median seeing. * Focal plane alignment (z): 2 mm is not critical if and only if the LGS WFS focus stage is not near a limit or end of travel. * Calibration Unit * Implies an on-axis point source at NGS focus, are there 3 off-axis point sources that can be fed into the LOWFS? Will these be available to use simultaneously with the LGS sources to simulate observing? This is a vital testing mode. * In addition to focus range to accomodate an ADC, phase retrieval (image sharpening) requires +/- 4 mm of defocus at f/15, psuedo pupil requires +/- 10 mm defocus @f/15 * Is there a Na layer at 150 km? Can the 80 km conjugate track to 90 km? ---++++ Sec. 3.7 LOWFS to AO Relay Alignment * Does aligning the LOWFS via the TWFS align all three LOWFS or just the one with the TWFS? ---++++ Sec 3.10 DAVINCI Science Instrument to AO Bench Alignment * Do you expect DAVINCI to have xyz adjustments for its kinematic mounts? * Why is there no pupil imaging mode for DAVINCI? It has proved very useful for K2AO ---++++ Sec 3.11 AO Bench Warm Enclosure Testing * What is the mechanism to align both science instrument detectors and the coronographic focal plane mask? ---++++ Sec 4.2 Summit Alignment Preparations * Who is responsible for deconstructing/decommissioning K2AO and NIRC2? * What is the proposed schedule? * What is the design load of K2 LNAS? How does it compare to the likely weight of the new AO enclosure, bench, and DAVINCI? * Are the design mods to K2 LNAS envisioned to be major? -- Main.PeterWizinowich - 09 Jun 2006
Edit
|
Attach
|
Watch
|
P
rint version
|
H
istory
:
r5
|
r4
<
r3
<
r2
<
r1
|
B
acklinks
|
V
iew topic
|
Raw edit
|
More topic actions...
Topic revision: r1 - 2010-04-15
-
JimLyke
Home
Site map
Antarctica web
Gattini web
SPRITE web
Cahill web
Gemini web
Keck web
MOSFIRE web
NGAO web
Main web
Palomar web
GASP web
PTF web
PalmLGS web
RoboAO web
SDC web
SEDM web
SWIFT web
TMAS web
Triplespec web
WaSP web
ZTF web
SNAP web
Sandbox web
Subaru web
PFS web
TMT web
More...
NGAO Web
Create New Topic
Index
Search
Changes
Notifications
RSS Feed
Statistics
Preferences
P
P
View
Raw View
Print version
Find backlinks
History
More topic actions
Edit
Raw edit
Attach file or image
Edit topic preference settings
Set new parent
More topic actions
Account
Log In
Register User
Edit
Attach
Copyright © 2008-2024 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding TWiki?
Send feedback