Check Out Positioner Failing Phenomen Charlie, Hrand and Matt looked into the reasons why some positioners were not working during some of the cold tests....
Going back to 5C Generated new Centers Link Lengths after going cold (xml 13) Generated Motor Maps from last 5C data (23rd and 27th April) xml 14 JohannesGross...
Bug Hunting MSIM failed again after target run with newly generated targets. Positioner 41 had a calculated angle of 418 We found a new case for Hrands...
Rerunning Targets at 17 C Updated motor maps with new data from last target run and kicked off targets (yesterday). Reran centers script with phi further...
Target Testings Tedious Start Targets with newly produced centers and link lengths ran until 145. MSIM Crashed with new (unkow) error Produced new targets...
Getting Ready For Targets Again Identified Pos. 21 yesterday as the trouble maker. Link lengths of pos 21 are way off, centers too. Reran centers script...
Debugging findCentroids First problem with MSIM stalling out on findCentroids is due to a DLL problem. Workaround: run MSIM from MS Visual Studio findCentroids...
MSIM Problems Target Convergence Testing is still not succeeding. One issue with findCentroids was due to Matlab running on TB computer eating up too much RAM...
Swapped Driver Boards on 2/24/2015 Charlie and Peter installed Driver Board (SN 02) onto the module. Re connected all flex print cables from Cobras to the...
Electronics Issues Over the past 2 weeks the electronics have been not behaving as expected and most of the time have behaved erratically (sometimes working normal...
Connect to camera using Remote CameraSetup NoCooling.lst Take test images using 2015 01 29 SingleExposure.lst Found .002s exposure was good for LED settings...
MOVE FROM CAHILL TO PHYSICS BUILDING HIGH BAY (SYNCOTRON) Peter and Charlie moved all hardware to the cold box located in Syncotron Test Cube w/ stages...
Released PFI CAD Models for Partner Use Attach CAD files to this page, `creating a link` to the file; organize into sections and headings as the list grows; comment...
Interval #8211; The combined time of the pulse duration and ringout time. One motor step occurs in one interval. Duration #8211; The length of time in which...