---++ Set E Focus Testing ---+++ Theta Focus * Re-cabled to set E (essentially set D, but with substitutions from set B for non-funcitonal postitioners) * frequency calibration completed (looks normal) * made new msim scripts * 2014_08_13_thetaTilt_setE.lst * 2014_08_13_phiTilt_setE.lst * Merged set D and set B xml database into a set E file 'setE_allMaps_081314.xml' * Set D = allMaps_072114_1_adj10 * Set B = allMaps_070114adj2 * Set E = the Set D map, but with pid 5,6 and 8 from Set B * Generated focus targets using setE map * Loaded setE xml into mSim and copied over Set E Theta Targets * Finished all 12 Theta targets with videos ---+++ Phi Focus * Copied over phi targets * Re-started mSim and loaded 2014_08_13_phiTilt_setE.lst * Everything ready to start the next morning ---++ mSim Code Update (Prior to Set E focus testing) ---+++ Summary of updates * If angle calculated beyond motor map value, it will extrapolate step count (instead of crashing) * Added check to verify that individual logs can open and will print error if it cannot open. * Added extra structure to the database * Cluster Map * All old xml database files are forward compatible -- Main.ChazMorantz - 13 Aug 2014
This topic: Subaru/PFS
>
WebHome
>
POSitionerEM
>
POSEM_AL
>
2014_08_13_SetD
Topic revision: r3 - 2014-08-14 - ChazMorantz
Copyright © 2008-2024 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.