Difference: FunctionalityRequests (1 vs. 6)

Revision 62015-11-25 - NadiaBlagorodnova

Line: 1 to 1
 
META TOPICPARENT name="Software"

Functionality list

Line: 18 to 18
 
  • Add field called 'INSTRUME' and 'TELESCOP' to the fits headers.
  • Add field to fits file called IMAGETYPE: BIAS, DOME, FLAT, OBJECT, OTHER, SKYFLAT,STD,WAVE
  • Add field called RDNOISE: The 2 MHz mode has ~20 e- of read noise, and a clear non-random signal. The 100 kHz mode has about 4 e- of read noise.
Added:
>
>
  • When the Fourshot is taking an image of the object in a specific band, the header should change to that band. At the moment the header has hardcoded the r-band data segment.
 -- NadiaBlagorodnova - 19 Nov 2015

Revision 52015-11-19 - NadiaBlagorodnova

Line: 1 to 1
 
META TOPICPARENT name="Software"

Functionality list

Added:
>
>
GUI
 
  • Create a GUI for the focus of the spectrograph. At the moment, we are running: SpecFocus.focus_loop from the console.
  • Add the option to do multiple exposures on the Fourshot GUI. It will allow to go deeper by stacking images.
Added:
>
>
  • Display somewhere the status of the shutter. At the moment our only guide is the elapsed exposure time.

LOGGING

 
  • Make the logs to be 'rolling'. Directing to another log file passed midnight.
Added:
>
>
TROUBLESHOOTING
 
  • For the 'Fourshot', fix the timing between the movement of the telescope and the exposure. The exposure shall start only after the telescope has been moved.
  • For the 'Fourshot', make sure there are no errors for short exposures (1 or 2s).
Deleted:
<
<
  • Add field called 'INSTRUME' and 'TELESCOP' to the fits headers.
  • Display somewhere the status of the shutter. At the moment our only guide is the elapsed exposure time.
 
Added:
>
>
Fits files
  • Add field called 'INSTRUME' and 'TELESCOP' to the fits headers.
  • Add field to fits file called IMAGETYPE: BIAS, DOME, FLAT, OBJECT, OTHER, SKYFLAT,STD,WAVE
  • Add field called RDNOISE: The 2 MHz mode has ~20 e- of read noise, and a clear non-random signal. The 100 kHz mode has about 4 e- of read noise.
 -- NadiaBlagorodnova - 19 Nov 2015 \ No newline at end of file

Revision 42015-11-19 - NadiaBlagorodnova

Line: 1 to 1
 
META TOPICPARENT name="Software"

Functionality list

Line: 8 to 8
 
  • For the 'Fourshot', fix the timing between the movement of the telescope and the exposure. The exposure shall start only after the telescope has been moved.
  • For the 'Fourshot', make sure there are no errors for short exposures (1 or 2s).
  • Add field called 'INSTRUME' and 'TELESCOP' to the fits headers.
Added:
>
>
  • Display somewhere the status of the shutter. At the moment our only guide is the elapsed exposure time.
  -- NadiaBlagorodnova - 19 Nov 2015 \ No newline at end of file

Revision 32015-11-19 - NadiaBlagorodnova

Line: 1 to 1
 
META TOPICPARENT name="Software"

Functionality list

  • Create a GUI for the focus of the spectrograph. At the moment, we are running: SpecFocus.focus_loop from the console.
Added:
>
>
  • Add the option to do multiple exposures on the Fourshot GUI. It will allow to go deeper by stacking images.
 
  • Make the logs to be 'rolling'. Directing to another log file passed midnight.
  • For the 'Fourshot', fix the timing between the movement of the telescope and the exposure. The exposure shall start only after the telescope has been moved.
  • For the 'Fourshot', make sure there are no errors for short exposures (1 or 2s).

Revision 22015-11-19 - NadiaBlagorodnova

Line: 1 to 1
 
META TOPICPARENT name="Software"

Functionality list

Line: 6 to 6
 
  • Make the logs to be 'rolling'. Directing to another log file passed midnight.
  • For the 'Fourshot', fix the timing between the movement of the telescope and the exposure. The exposure shall start only after the telescope has been moved.
  • For the 'Fourshot', make sure there are no errors for short exposures (1 or 2s).
Added:
>
>
  • Add field called 'INSTRUME' and 'TELESCOP' to the fits headers.
  -- NadiaBlagorodnova - 19 Nov 2015 \ No newline at end of file

Revision 12015-11-19 - NadiaBlagorodnova

Line: 1 to 1
Added:
>
>
META TOPICPARENT name="Software"

Functionality list

  • Create a GUI for the focus of the spectrograph. At the moment, we are running: SpecFocus.focus_loop from the console.
  • Make the logs to be 'rolling'. Directing to another log file passed midnight.
  • For the 'Fourshot', fix the timing between the movement of the telescope and the exposure. The exposure shall start only after the telescope has been moved.
  • For the 'Fourshot', make sure there are no errors for short exposures (1 or 2s).

-- NadiaBlagorodnova - 19 Nov 2015

 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright © 2008-2021 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.